The most successful Hg analyzer in the market

Easy to use

conocer chica jovenes The DMA-1 is based on the principles of sample thermal decomposition, mercury amalgamation and atomic absorption detection.
It is extremely easy to use: just weigh your sample, load it onto the instrument and press ‘start’. The DMA-1 is so simple to use that it can be operated in the field, not only in the analytical laboratory.
All the DMA-1 components, such as the catalytic furnace, amalgamator and spectrophotometer, are easily accessible for routine cleaning and maintenance.

hat jemand erfahrungen mit binären optionen

http://www.energylease.fr/viliv/5632 The DMA-1 is compliant with the US EPA method 7473 (Mercury in solids and solutions by thermal decomposition, amalgamation, and atomic absorption spectrophotometry), with ASTM method D-6722-01 (Total mercury in coal and coal combustion residues) and ASTM method D-7623-10 (Total mercury in crude oil).

rencontre femme mariée québec

DMA-1 user interface

watch DMA-1 user interfaceThe terminal runs Milestone’s unique EasyCONTROL software, providing simple and intuitive, but extremely flexible and powerful control over the analytical process.

go to link

http://fbmedical.fr/aftepaes/3521 All sample parameters, including furnace temperatures, method profiles, absorbance signals, results, and calibrations are saved. They can be viewed, easily transferred using a USB memory stick or integrated to LIMS Laboratory Information Management Systems.
EasyCONTROL software includes the unique AutoBLANK feature. If, following the analysis of a sample with very high mercury contents, the pre-set blank level is exceeded; EasyCONTROL will automatically run blank cycles until the pre-set blank level is achieved.

focus on the family dating after divorce

http://vagnvagensbygg.se/firmenit/3300 EasyCONTROL allows the operator to designate certain samples as reference, or QC samples.
Once a sample is designated as a reference, a known concentration value is entered. If the analysis of that sample yields a concentration outside the acceptable range specified by the operator, EasyCONTROL can be pre-set to either continue, stop, or pause the analysis of the remaining samples.

go to link


  • Download catalog
  • Play video
  • Request more info
  • Request application